top of page
C-7 893633
LOW VOLTAGE SYSTEMS

Installed HID Prox Pro Plus at front entrance mullion

Legacy Sielox AC-900 Main controller connected to Legacy Input/Output board

surface mount Mag-Lock, 600 lbs hold force

Local emergency door release override, additionally wired as alarm input to access control

Interior Vault location (early SCIF type area)

Install Biometric fingerprint reader and electric lever lock

All control and power equipment must be installed within the secure area

Interior mag lock, door contact for access control system, legacy alarm system contact

Local doro release, wired as input to access control system